Japan · JIS
Channel · CH
JIS G3192:2024 · 16 sections
C 75×40×5×7JIS G3192:2024
6.92Unit mass · kg/m
0.3Surface area · m²/m
8.818Section area · cm²
20.1Section modulus · cm³
Calculation
—Unit weight
—Total weight
—Total price
Formula
- A = …
Theoretical weight from the section area × density; mill tolerances apply.
DetailsC 75×40×5×7
depth
h75mmflange width
b40mmweb thickness
t15mmflange thickness
t27mmroot radius
r8mmtoe radius
r14mmSection area
A8.818cm²Mass per metre
W6.92kg/mSecond moment of area, x-x
Ix75.3cm⁴Elastic section modulus, x-x
Wx20.1cm³Radius of gyration, x-x
ix2.92cmSecond moment of area, y-y
Iy12.2cm⁴Elastic section modulus, y-y
Wy4.5cm³Radius of gyration, y-y
iy1.17cmPlastic section modulus, x-x
Zx20.1cm³Plastic section modulus, y-y
Zy4.47cm³Surface area per metre
S0.3m²/m↑↓EnterEsc